Home > Products > Digital and Analog > Sensors > Magnetic Pickups > MP > Ordering Information


LMPC-Amplified Magnetic Pickup
MP-Standard Magnetic Pickups
 
:: MP Ordering Information ::
Please use the Ordering Information chart below to select the part number you're interested in purchasing. 
Simply click on the part number to go to the purchase page for that product.

MODEL NO.

DIMENSIONS

1-VOLT 
THRESHOLD
SPEED (1)

MINIMUM
GEAR
PITCH (2)

TEMP
 RANGE °C

OUTPUT 
IMPEDANCE

PART NO.

MP-25TA

135 in/sec
1000 RPM
60T 24 D.P.
Ref. Gear

48 D.P.

-40 to +107

130 Ohms
 +/-20%
15 mH

MP25TA00

MP-37TA

33 in/sec
200 RPM
60T 20 D.P.
Ref. Gear

32 D.P. -40 to +107

340 Ohms
+/-20%
44 mH

MP37TA00

MP-37TAC1
(7)

33 in/sec
200 RPM
60T 20 D.P.
Ref. Gear

32 D.P. -40 to +107

340 Ohms
+/-20%
44 mH

MP37TAC1
MP-37CA

30 in/sec
180 RPM
60T 20 D.P.
Ref. Gear

32 D.P. -40 to +107

300 Ohms
+/-30%
65 mH

MP37CA00
MP-62TA 10 in/sec
50 RPM
60T 16 D.P.
Ref. Gear
24 D.P. -40 to +107

1200 Ohms
 +/-20%
400 mH

MP62TA00
MP-62TAC1
(7)
10 in/sec
50 RPM
60T 16 D.P.
Ref. Gear
24 D.P. -40 to +107

1200 Ohms
 +/-20%
400 mH

MP62TAC1
MP-62TB 20 in/sec
100 RPM
60T 16 D.P.
Ref. Gear
24 D.P. -40 to +107

1200 Ohms
+/-20%
400 mH

MP62TB00
MP-75TX
Explosion
Proof (3)
30 in/sec
100 RPM 
60T 10 D.P.
Ref. Gear
12 D.P. -40 to +107

230 Ohms
+/-20%
100 mH

MP75TX00

NOTES:

1) Surface speed of listed reference gear to produce 0.8 volt peak min., open-circuit output @ 0.005" air-gap.
2) Gear pitch where output will drop to 40-60% of that generated by the reference gear size, at the same surface speed.
3) UL Listed CSA Certified, Class I Group A, B, C and D; Class II Group E, F and G. (VDO Control Systems, Inc.) PN#AIRPAX/70085-1010-005, UL File #E40545 (N), CSA File #042648.

4) Polarity, all pickups: white output lead goes positive with respect to black when target approaches pole.

5) 2-Wire shielded cable is recommended for all magnetic pickup outputs. Connect the shield to the “COMMON” or “GROUND” terminal of the instrument being used and leave the shield un-connected at the pickup. Magnetic Pickup signal leads should never be run in conduit, troughs, or bundles with other power or control voltage lines.

6) Lead length of magnetic pickup should not be extended. An in-line pre-amplifier (ASTC) can be placed on the end of the provided length which would allow longer length after the in-line pre-amplifier.

7) M12 unit color codes for 1 meter cable is:

PIN 3 - Blue (-)
PIN 4 - Black (+)
PIN 2 - NC
PIN 1 - NC


Privacy Policy | Terms and Conditions | Warranty Statement
Repair Order Policy | Return Policy

in Spanish in French in German in Italian in Chinese Search home